Overview

Omron Hem-4030 Upper Arm  BP Monitor Omron Hem-4030 Upper Arm  BP Monitor

Omron Hem-4030 Upper Arm BP Monitor

Quantity Description: packet of 1 Device
Manufacturer: Omron Healthcare India Pvt Ltd
Price: ₹ 1750.0

Information about Omron Hem-4030 Upper Arm BP Monitor

Omron HEM-4030 Upper Arm BP Monitor is a compact manual inflation blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly.

Features of Omron HEM-4030 Upper Arm BP Monitor:
Measurement method: Oscillometric method
Accuracy pressure 3 mmHg, Pulse 5 percentage of display reading
Memory - 14 sets of readings
Main unit, medium cuff (146 millimeter 446 millimeter), instruction manual, battery set
1 year manufacturer s warranty from the date of purchase

Related Products

Popular Questions & Answers

I suffer from diabetes and HBP. After a stressful day, I checked by BP by OMRON HEM-7111 numerous times on my left arm but every time it showed an error, while for anybody else it showed the correct reading. A Then when I tried on my right arm, it showed the reading as 198/108. Why was it so? Please put some light as to what could be the reason.

DHMS (Diploma in Homeopathic Medicine and Surgery)
Homeopath, Ludhiana
I suffer from diabetes and HBP. After a stressful day, I checked by BP by OMRON HEM-7111 numerous times on my left ar...
To use these electronic BP machines to get correct reading, one should follow strict rules while using them like 1. Size of Cuff A BP cuff that is too large will give falsely low readings, while an overly small cuff will provide readings that are falsely high The most practical way to quickly and properly size a BP cuff is to pick a cuff that covers two-thirds of the distance between your patient?s elbow and shoulder. 2. Incorrectly position of Patient's bodyA seated upright position provides the most accurate blood pressure, as long as the arm in which the pressure is taken remains at the patient?s side. Patients lying on their side, or in other positions, can pose problems for accurate pressure measurement. To correctly assess BP in a side lying patient, hold the BP cuff extremity at mid heart level while taking the pressure. In seated patients, be certain to leave the arm at the patient?s side. 3. Placed the cuff incorrectly The standard for blood pressure cuff placement is the upper arm using a cuff on bare skin with a stethoscope placed at the elbow fold over the brachial artery.The patient should be sitting, with the arm supported at mid heart level, legs uncrossed, and not talking. 4. Do not be Prejudiced Prejudice for normal readings significantly contributes to inaccuracies in blood pressure measurement. 5. You?re not factoring in electronic units correctly Electronic blood pressure units also called Non Invasive Blood Pressure (NIBP) machines, sense air pressure changes in the cuff caused by blood flowing through the BP cuff extremity. Sensors estimate the Mean Arterial Pressure (MAP) and the patient?s pulse rate. Software in the machine uses these two values to calculate the systolic and diastolic BP. To assure accuracy from electronic units, it is important to verify the displayed pulse with an actual patient pulse. Differences of more than 10 percent will seriously alter the unit?s calculations and produce incorrect systolic and diastolic values on the display screen. So my point to explain all this above 5 points is that these electronics gadgets can only be helpful if we follow strict guidelines as these gadgets are provided strict instructions in their software but we people every time chk our BP in different bodily conditions Blood pressure readings in the right and left arms that differ by a few points aren?t anything to worry about. It?s actually quite normal. A difference of more than 10 points, though, could suggest trouble.In younger people, side-to-side differences in blood pressure can occur when a muscle or something else compresses an artery supplying the arm, or by a structural problem that prevents smooth blood flow through an artery.In older people, it?s usually due to a blockage arising from atherosclerosis, the artery-clogging disease process at the root of most heart attacks, strokes, peripheral artery disease, and other cardiovascular conditions, but the possibility of a damaged BP monitor cannot be ruled out in your case- Here are a few tips to help you start monitoring your blood pressure at home: 1. Avoid caffeine, alcohol, and nicotine during the 30 minutes before you take your reading. 2. Sit quietly for a few minutes with your back supported and your feet on the floor. 3. When making the measurement, rest your arm so your elbow is at the level of your heart. 4. Wrap the cuff over the bare skin of your upper arm. Measure your blood pressure according to the machine?s instructions. Leave the deflated cuff in place, wait a minute, then take a second reading. If the readings are close, average them. If not, take a third reading and average the three. Repeat the procedure in the other arm. 4. If the blood pressure readings in your arms are off by more than 10 or 15 points, mention this at your next doctor visit and ask your doctor or nurse to check both arms.
1 person found this helpful

I use omron hem 7121j machine for bp reading. I have monitored bp for month. It came in range 115/75 to 126/90 or 127/95. I was taking metosartan 50 tablet for 25 days. After taking medicine my bp reading still came in between above mentioned range. After few days I had left shoulder pain so I went to doc and when I check bp in clinic it was 152/110, 158/97. Why is there sudden change in bp.

DHMS (Diploma in Homeopathic Medicine and Surgery)
Homeopathy Doctor, Chandigarh
I use omron hem 7121j machine for bp reading. I have monitored bp for month. It came in range 115/75 to 126/90 or 127...
Life style modification along with medication is need of the hour ,avoid minimal sugar ,salt, maida,fried, better to include two third fresh seasonal local fruits and vegetables in your major meals, regular walk to control bp.

Mild pain in the right chest. Bp as monitored on omron bp monitor machine is 160/110. please suggest which specialist to consult.

MD (physician), D.card (clinical cardiology ),CCEBDM(diabetology), D.card (pgdcc)
Non-invasive Cardiologist, Ahmednagar
Mild pain in the right chest. Bp as monitored on omron bp monitor machine is 160/110. please suggest which specialist...
Hello please visit cardiologist nearby. And also do bp monitoring -check your bp daily for 7 days at different timings. Your cardilogist may ask you to do some tests as you are young to have high bp. To rule out causes for high bp. If hypertension is confirmed he may start you with bp lowering medicines. Reduce your salt intake to minimum. You have not mentioned the weight here but reducing weight and starting exercize like walking may help you to lower your bp. Thanks and regards. Wish you good health.

Hello I am always tachycardia on the monitor I am not sure what this means could please explain this to me in detail.

BHMS
Homeopath, Gwalior
Hello I am always tachycardia on the monitor I am not sure what this means could please explain this to me in detail.
Tachycardia refers to a high resting heart rate. In general, a resting adult heart beats between 60 and 100 times per minute. When an individual has tachycardia, the upper or lower chambers of the heart beat significantly faster. When the heart beats too rapidly, it pumps less efficiently and blood flow to the rest of the body, including the heart itself, is reduced. Because the heart is beating quicker, the muscles of the heart, or myocardium, need more oxygen. If this persists, oxygen-starved myocardial cells can die, leading to a heart attack.
2 people found this helpful
Having issues? Consult a doctor for medical advice